Scenario #5
Customer owns painting company that performs bridge renovations. In order to paint the bridge a large platform is suspended below it to allow personnel access to the underside. Platform is suspended using 20 suspension points spread throughout. Customer would like to continuously monitor each point in order to avoid accidental overloads as people and equipment move from one side of the platform to the other.
His engineer has informed him that the maximum load that can be applied to a single point if 2 tons and would requires a safety factor of 5:1 for any part added to the structure.
Quote 1:
Ron CraneMaster 6000 Wireless Load Monitoring System
20 x 2t capacity wireless dynamometers with 5:1 safety ratio
Central Radio Receiver for use with Mac or Windows Laptop.
Quote 2:
Ron CraneMaster 6000 Wireless Load Monitoring System
20 x 2t capacity wireless dynamometers with 5:1 safety ratio
Portable Radio Receiver for use with a tablet or smartphone
It may be possible that having a centrally located PC may not be feasible for this customer for this reason we have also offered him a Portable Radio Receiver. The Portable Radio Receiver can be added to the Central Radio Receiver or can operate independently.