Scenario #2
The Customer would like to weigh the amount of molten material in a ladle at his foundry. He would also like to record the weight of each ladle for later analysis and record keeping on his PC. Total weight of ladle and molten material is 45 tons.
Quote:
Ron 2501 S-50 50 ton shackle type dynamometer
Heat Shield
Thermometer
Data Logger
USB adaptor
As explained in our options section, the heat shield can only delay the rise in the load cell’s internal temperature, it cannot prevent it. For this reason we always include the internal thermometer option so the operator can monitor the temperature and prevent it from exceeding the maximum operational temperature.