Specifications
|
Options
|
Safety Factor: 5:1. Each system proof-loaded to 200% of capacity (certified).
Switching Nature: Normally open and/or normally closed.
Rating: 0.5A @ 50 VDC, 0.5A @ 125 VAC.
Life Expectancy: Electrical: over 1 million operations. Mechanical: over 5 million operations.
|
|
Approved by: UL, CSA, Semko VDE.
Environment: Weatherproof, NEMA 4, IP 65.
Temperature Range: -4°F to +175°F (-20°C to + 80°C).
Cable Length: 9.5' (3m).
Material: High strength, low alloy steel
|
|
Wiring
Options:
Additional detection point
Fatigue rated structure
|
| RON 1000 - S |
 |
|
| 15.08.07 |
| Cat no. | Cap. | D Min. | A | E Max. | F Max. | C Max. | B Max. | | tons | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch | mm | inch |
| S-002 | 0.25 | 25 | 1 | 60 | 2 3/8 | 7 | 5/16 | 19 | 3/4 | 100 | 4 | 202 | 8 | | S-005 | 0.5 | 7 | 5/16 | 19 | 3/4 | | S-007 | 0.75 | 7 | 5/16 | 19 | 3/4 | | S-008 | 0.8 | 7 | 5/16 | 19 | 3/4 | | S-01 | 1.0 | 7 | 5/16 | 19 | 3/4 | | S-012 | 1.25 | 7 | 5/16 | 19 | 3/4 | | S-015 | 1.5 | 9 | 3/8 | 21 | 13/16 | | S-016 | 1.6 | 9 | 3/8 | 21 | 13/16 | | S-02 | 2.0 | 11 | 7/16 | 23 | 7/8 | | S-025 | 2.5 | 13 | 9/16 | 25 | 1 | | S-03 | 3.0 | 40 | 1 9/16 | 111 | 4 3/8 | 7 | 5/16 | 22 | 7/8 | 155 | 6 1/8 | 272 | 10 3/4 | | S-032 | 3.2 | 7 | 5/16 | 22 | 7/8 | | S-04 | 4 | 7 | 5/16 | 22 | 7/8 | | S-05 | 5 | 7 | 5/16 | 22 | 7/8 | | S-06 | 6 | 9 | 3/8 | 24 | 15/16 | | S-063 | 6.3 | 9 | 3/8 | 24 | 15/16 | | S-08 | 8 | 11 | 7/16 | 26 | 1 | | S-10 | 10 | 13 | 9/16 | 28 | 11/8 |
WHEN USING THE OVERLOAD DETECTOR, USE LIFTING ACCESSORIES WITH S.W.L. (SAFE WORKING LOAD) EQUAL TO, OR GREATER THAN THAT OF THE DETECTOR.
Eilon Engineering reserves the right to make changes without notice.
|
|